Catalog · table
Generator
One row per generator per calendar year, from Schedule 3 of Form EIA-860: nameplate, summer and winter capacity, prime mover, fuels, the dates it entered service and retired, operational status and combustion technology. The key is (year, plant_id, generator_id), because generator_id is unique only within a plant. From 2009 the form splits operable, proposed and retired generators across three sheets, unioned here into one table with generator_status_group recording which: summing capacity_mw without filtering that column adds installed, proposed and retired capacity into one number
- Described
- by Base dos Dados
- Publisher
- Energy Information Administration (EIA)
- Source page
- basedosdados.org
- Licence
- Unknown · reuse unknown
- Period
- 2001 to 2025 (by year) · by Base dos Dados
- Area
- United States
- Rows
- 627,957
- Source updated
- 2026-09-08
- Topics
- Infrastructure and transportation
- Catalog level
- L1 · described
How to use
Connect your agent to Evidence's MCP server and ask in plain language. The agent finds this table, reads its columns and caveats, and runs the query for you.
claude mcp add --transport http -s user evidence \
https://mcp.evidence.so/mcp \
--header "Authorization: Bearer $MCP_API_KEY"Then ask, for example:
What does the table Generator contain, and how do I query it?
Columns (54)
| Name | Type | Role | Description | Meaning |
|---|---|---|---|---|
| year | integer | time | Ano-calendário do inventário | Time: reference period, by year |
| plant_id | string | reference | Código da usina geradora atribuído pela EIA | — |
| generator_id | string | identifier | Identificador do gerador dentro da usina | — |
| plant_name | string | attribute | Nome da usina tal como declarado | — |
| utility_id | string | reference | Código da empresa operadora atribuído pela EIA | — |
| utility_name | string | attribute | Nome da empresa operadora | — |
| state_abbreviation | string | dimension | Sigla postal de duas letras do estado | — |
| state_id | string | reference | Código FIPS de duas posições do estado | Coded by Estado (id_state) · verified |
| county_name | string | attribute | Nome do condado onde o gerador está localizado | — |
| county_id | string | reference | Código FIPS de cinco posições do condado | Coded by Condado (id_county) · verified |
| generator_status_group | string | dimension | Grupo do gerador no formulário: em operação, proposto ou aposentado | Coded by bdd:us_eia_electricity.generator/generator_status_group · verified |
| operational_status_code | string | dimension | Código da situação operacional do gerador | Coded by bdd:us_eia_electricity.generator/operational_status_code · verified |
| unit_id | string | reference | Identificador da unidade a que o gerador pertence | — |
| ownership_code | string | dimension | Código da forma de propriedade do gerador | Coded by bdd:us_eia_electricity.generator/ownership_code · verified |
| sector_id | string | reference | Código do setor econômico da usina | Coded by bdd:us_eia_electricity.generator/sector_id · verified |
| sector_name | string | attribute | Nome do setor econômico da usina | — |
| prime_mover_code | string | dimension | Código da máquina primária do gerador | Coded by bdd:us_eia_electricity.generator/prime_mover_code · verified |
| technology_description | string | attribute | Descrição da tecnologia de geração | Coded by bdd:us_eia_electricity.generator/technology_description · verified |
| capacity_mw | decimal | measure | Capacidade nominal de placa do gerador | — |
| summer_capacity_mw | decimal | measure | Capacidade líquida do gerador em condições de verão | — |
| winter_capacity_mw | decimal | measure | Capacidade líquida do gerador em condições de inverno | — |
| minimum_load_mw | decimal | measure | Carga mínima de operação estável do gerador | — |
| planned_new_capacity_mw | decimal | measure | Capacidade de placa prevista para o gerador proposto | — |
| turbines_num | integer | measure | Número de turbinas do gerador | — |
| turbines_inverters_hydrokinetics | integer | measure | Número de turbinas, inversores ou dispositivos hidrocinéticos | — |
| energy_source_code_1 | string | dimension | Código do primeiro combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_1 · verified |
| energy_source_code_2 | string | dimension | Código do segundo combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_2 · verified |
| energy_source_code_3 | string | dimension | Código do terceiro combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_3 · verified |
| energy_source_code_4 | string | dimension | Código do quarto combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_4 · verified |
| energy_source_code_5 | string | dimension | Código do quinto combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_5 · verified |
| energy_source_code_6 | string | dimension | Código do sexto combustível ou fonte de energia do gerador | Coded by bdd:us_eia_electricity.generator/energy_source_code_6 · verified |
| can_burn_multiple_fuels | string | dimension | Indica se o gerador pode queimar mais de um combustível | Coded by bdd:us_eia_electricity.generator/can_burn_multiple_fuels · verified |
| can_cofire_fuels | string | dimension | Indica se o gerador pode co-queimar combustíveis | Coded by bdd:us_eia_electricity.generator/can_cofire_fuels · verified |
| switch_oil_gas | string | dimension | Indica se o gerador pode alternar entre óleo e gás | Coded by bdd:us_eia_electricity.generator/switch_oil_gas · verified |
| operating_date | date | time | Data em que o gerador entrou em operação comercial | Time: event, by day |
| retirement_date | date | time | Data em que o gerador foi aposentado | Time: event end, by day |
| planned_retirement_date | date | time | Data prevista de aposentadoria do gerador | Time: by day |
| planned_operating_date | date | time | Data prevista de entrada em operação do gerador proposto | Time: by day |
| carbon_capture | string | dimension | Indica se o gerador possui captura de carbono | Coded by bdd:us_eia_electricity.generator/carbon_capture · verified |
| solid_fuel_gasification | string | dimension | Indica se o gerador usa gaseificação de combustível sólido | Coded by bdd:us_eia_electricity.generator/solid_fuel_gasification · verified |
| pulverized_coal_tech | string | dimension | Indica tecnologia de carvão pulverizado | Coded by bdd:us_eia_electricity.generator/pulverized_coal_tech · verified |
| fluidized_bed_tech | string | dimension | Indica tecnologia de leito fluidizado | Coded by bdd:us_eia_electricity.generator/fluidized_bed_tech · verified |
| stoker_tech | string | dimension | Indica tecnologia de grelha alimentadora | Coded by bdd:us_eia_electricity.generator/stoker_tech · verified |
| other_combustion_tech | string | dimension | Indica outra tecnologia de combustão | Coded by bdd:us_eia_electricity.generator/other_combustion_tech · verified |
| subcritical_tech | string | dimension | Indica ciclo a vapor subcrítico | Coded by bdd:us_eia_electricity.generator/subcritical_tech · verified |
| supercritical_tech | string | dimension | Indica ciclo a vapor supercrítico | Coded by bdd:us_eia_electricity.generator/supercritical_tech · verified |
| ultrasupercritical_tech | string | dimension | Indica ciclo a vapor ultrassupercrítico | Coded by bdd:us_eia_electricity.generator/ultrasupercritical_tech · verified |
| duct_burners | string | dimension | Indica presença de queimadores de duto | Coded by bdd:us_eia_electricity.generator/duct_burners · verified |
| bypass_heat_recovery | string | dimension | Indica se a recuperação de calor pode ser contornada | Coded by bdd:us_eia_electricity.generator/bypass_heat_recovery · verified |
| associated_combined_heat_power | string | dimension | Indica se o gerador integra unidade de cogeração | Coded by bdd:us_eia_electricity.generator/associated_combined_heat_power · verified |
| topping_bottoming_code | string | dimension | Posição do gerador no ciclo de cogeração | Coded by bdd:us_eia_electricity.generator/topping_bottoming_code · verified |
| synchronized_transmission_grid | string | dimension | Indica se o gerador é sincronizado com a rede de transmissão | Coded by bdd:us_eia_electricity.generator/synchronized_transmission_grid · verified |
| rto_iso_lmp_node_id | string | reference | Identificador do nó de preço marginal local no ISO ou RTO | — |
| data_maturity | string | technical | Grau de consolidação dos valores da linha | Coded by bdd:us_eia_electricity.generator/data_maturity · verified |
Caveats
methodology · warning · capacity_mw, generator_status_group
Curated by Evidence · full text through the MCP
other · operating_date, retirement_date, planned_retirement_date, planned_operating_date
Curated by Evidence · full text through the MCP
other · associated_combined_heat_power
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · bypass_heat_recovery
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · can_burn_multiple_fuels
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · can_cofire_fuels
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · carbon_capture
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · county_id
Resolvido a partir do nome do condado e da sigla do estado contra br_bd_diretorios_us.county — o formulário publica o nome, nunca o código FIPS. Nulo quando o nome não resolve, sobretudo nos condados históricos de Connecticut, que o formulário ainda usa e que o diretório substituiu pelas regiões de planejamento de 2022
other · data_maturity
final = arquivo definitivo; provisional = early release, substituído por uma revisão final posterior; incremental_ytd = arquivo mensal do ano corrente, substituído a cada nova publicação. Derivado do nome do arquivo publicado, único lugar onde a EIA registra isso
other · duct_burners
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · energy_source_code_1
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · energy_source_code_2
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · energy_source_code_3
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · energy_source_code_4
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · energy_source_code_5
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · energy_source_code_6
Combustíveis são declarados em até seis colunas por ordem de importância; as posições não usadas ficam nulas
other · fluidized_bed_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · generator_id
Único apenas dentro de uma usina: a chave da tabela é (year, plant_id, generator_id)
other · generator_status_group
A partir de 2009 o formulário separa os três grupos em planilhas distintas e o valor é a planilha de origem. Antes disso operantes e aposentados vêm em uma planilha só, e o grupo é derivado de operational_status_code pelo próprio vocabulário da EIA
other · operating_date
O formulário publica apenas mês e ano; o dia é fixado em 01
other · other_combustion_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · planned_operating_date
O formulário publica apenas mês e ano; o dia é fixado em 01
other · planned_retirement_date
O formulário publica apenas mês e ano; o dia é fixado em 01
other · plant_id
Identificador de usina atribuído pela EIA. É a chave de junção estável entre todas as tabelas deste conjunto e entre os formulários EIA-860 e EIA-923; permanece com a usina através de mudanças de proprietário e de nome. STRING porque é um identificador, não uma quantidade
other · pulverized_coal_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · retirement_date
O formulário publica apenas mês e ano; o dia é fixado em 01
other · solid_fuel_gasification
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · state_id
Resolvido a partir da sigla postal publicada
other · stoker_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · subcritical_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · supercritical_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · switch_oil_gas
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · synchronized_transmission_grid
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · ultrasupercritical_tech
Indicador Y/N tal como publicado; mantido como STRING porque a fonte também usa códigos e brancos que um booleano descartaria
other · utility_id
Identificador de empresa atribuído pela EIA, estável entre formulários e anos. STRING porque é um identificador, não uma quantidade
other · year
Coluna de particionamento; corresponde ao ano do arquivo anual de origem
urn:table:bdd:us_eia_electricity.generator · metadata by Evidence under CC BY 4.0; the data keeps its publisher's licence.